CTA’s Go Electric Truckee Tahoe program hosted an in-person heat pump training in Truckee on July 21st and 22nd for five contractors. The class involved both in-class lectures and a site visit, and was focused on building electrification, primarily through heat pump adoption, in our cold-climate, snowy mountain region. The course instructor, Dan Perunko of Balance Point Home Performance, both an experienced contractor and educator, specializes in heat pump technology and building efficiency and has worked extensively in the Truckee Tahoe area.
The site visit was to a local home that currently uses natural gas for water and space heating. Dan walked trainees through his process of diagnosing the current status of the home’s efficiency and determining its feasibility for an all electric retrofit project. To do so, he performed tests on the static pressure in the ducting, fan power, and air flow by evaluating the amount of air each vent was moving with an air flow capture hood. Dan also conducted a blower door test to determine how well the building was air sealed, which is important for overall building energy performance. Participants received hands-on experience with this equipment, and learned about their pros and cons compared to other, similar devices.
From his testing, Dan was able to determine that the existing ducting system was underperforming, and there were likely significant leaks that would need to be sealed or ducting replaced to improve energy efficiency. Additionally, likely areas for the outdoor condenser unit to be located were identified to ensure that it would be protected from the high snow loads we see in the Truckee Tahoe region. It was also important to note that cold-weather rated heat pump HVAC units would be required to provide ample heat during winter months. Finally, Dan walked attendees through how he would retrofit the existing natural gas water heater with a heat pump water heater, which was located in the garage. In his conclusion, Dan informed the attendees that the home was a great candidate for electrification, but would need improvements in insulation and duct sealing to optimize the energy efficiency savings resulting from heat pump retrofits.
There was a range of different specializations between attending contractors, including electricians, HVAC contractors, and a general contractor. During the whole site-visit, contractors were very engaged, asking questions and considering the different kinds of scenarios and issues that they may run into when performing an all-electric retrofit in Truckee Tahoe. This was the third contractor heat pump training hosted by CTA under this program, and the second that included a site visit. Attending contractors that currently work on heat pump retrofits were added to the participating contractors resource page on our website. If you’d like to learn more about this program, are a contractor interested in our trainings, or are a home or building owner curious about going all electric, please reach out to cta@sierrabusiness.org, and follow along on our LinkedIn page here!